环境风洞阻塞比对冷却模块空气侧流场的影响
Effect of Climate Wind Tunnel Blockage on Air-side Flowfield of Cooling Module
投稿时间:2016-03-22  修订日期:2017-06-26
DOI:10.11908/j.issn.0253-374x.2017.09.017     稿件编号:    中图分类号:U467.1
 
摘要点击次数: 114    全文下载次数: 93
中文摘要
      为研究不同环境风洞阻塞比对冷却系统试验的影响,通过数值模拟,建立1:1环境风洞模型及整车模型,分析不同阻塞比下冷却模块空气侧流场及前端的速度轮廓。结果表明:随着阻塞比增高,散热器表面风速分布发生变化,而其速度均匀性变化不大,当阻塞比大于0.486时,通过散热器的冷却空气流量有明显下降,降幅达5%;车辆前端的速度轮廓由于阻塞效应的存在发生偏移,且不同区域的偏移量并不一致,因此,对于环境风洞需要根据不同的试验目标进行阻塞比修正。
英文摘要
      Based on numerical simulation, it created a 1:1 scaled model of the climate wind tunnel and the passenger car, to investigate the effect of climate wind tunnel blockage on the cooling system experiment, and analyze the air-side flowfield of cooling module and the frontal velocity profile. The results indicate that, along with the increase of blockage ratio, the velocity distribution on the windward surface of radiator will make a difference, but little change for the uniformity index of velocity distribution. As the blockage surpasses 0.486, the air mass flow through the radiator has an obvious decrease, even up to 5%. Due to the blockage effect, the frontal velocity profile exists an offset, which is inconsistent in different positions. Consequently, the climate wind tunnel needs to perform a blockage correction according to the different experimental targets.